Profoil in battened floor installation.

Battened Floor Heating System

Battened floor section drawing for Profoil.

Profoil™ Battened Floor Panels are manufactured to meet the client’s individual project requirements and hence provide a totally flexible, bespoke solution that enables specific design and performance criteria to be achieved.

Timber battens of a uniform thickness are fixed to the level concrete slab at prescribed spacings. Profoil™ Battened Floor Panels (of the same thickness as the timber battens) are then fitted between the battens and a tongued & grooved chipboard or a timber floor finish is then applied.

A similar system can be used for sprung floors, although the flooring manufacturer’s recommendations regarding compatibility with warm water underfloor heating systems should be considered.

The following table provides some necessary information to assist in the decision making process:

Insulation
Material
Panel
Thickness
(mm)
Panel
Width
(mm)
Edge
Detail
For Pipe
Diameter
(mm)
Groove
Spacing
(pipe centres)
Thermal
Conductivity
(W/mK)
Compressive
Strength*
(kPa)
Expanded Polystyrene
(BS EN 13163)
to suit:   * at 10% compression
EPS 70 any batten spacing square any any 0.038 70
EPS 100 any batten spacing square any any 0.036 100
EPS 150 any batten spacing square any any 0.035 150
EPS 200 any batten spacing square any any 0.034 200
Extruded Polystyrene
(BS EN 13164)
to suit:  
XPS 2 from 20mm batten spacing square any any 0.029 250 ≤ 40mm
300 ≥ 50mm
XPS 3 from 30mm batten spacing square any any 0.029 300 ≤ 40mm
350 ≥ 50mm
XPS 4 from 50mm batten spacing square any any 0.030 ≤ 60mm 480
0.032    70-80mm 480
0.033 ≤ 90mm 480

Terms and Conditions © Epic Insulation, All Rights Reserved